[1]馮占江,陳利,李春梅,等.428電纜鹽堿侵蝕故障研究[J].石油管材與儀器,2018,4(03):88-91.[doi:10.19459/j.cnki.61-1500/te.2018.03.023]
             FENG Zhanjiang,CHEN Li,LI Chunmei,et al.Research of 428# Cable Fault Caused by Salt and Alkali Erosion[J].Petroleum Tubular Goods & Instruments,2018,4(03):88-91.[doi:10.19459/j.cnki.61-1500/te.2018.03.023]
            點擊復制

            428電纜鹽堿侵蝕故障研究
            分享到:

            《石油管材與儀器》[ISSN:2096-0077/CN:61-1500/TE]

            卷:
            4
            期數:
            2018年03期
            頁碼:
            88-91
            欄目:
            經驗交流
            出版日期:
            2018-06-20

            文章信息/Info

            Title:
            Research of 428# Cable Fault Caused by Salt and Alkali Erosion
            文章編號:
            2096-0077(2018)03-0088-04
            作者:
            馮占江陳利李春梅施玉林
            中石化地球物理公司勝利分公司儀器管理中心 山東 東營 257000
            Author(s):
            FENG Zhanjiang CHEN Li LI Chunmei SHI Yulin
            Sinopee Geophysieal Company Shengli Branch, Dongying, Shandong 257086, China
            關鍵詞:
            電纜鹽堿水域故障測試維修 衰減
            Keywords:
            cablesaline and alkali waters fault test maintenance attenuation
            分類號:
            P631.4
            DOI:
            10.19459/j.cnki.61-1500/te.2018.03.023
            文獻標志碼:
            A
            摘要:
            當地震施工遇到鹽堿水域時,有的428采集鏈的電纜不可避免的會浸泡在鹽堿水中,由于鹽堿水較強的侵蝕性,導致很多428電纜出現性能指標故障。與正常428電纜的衰減、 串音和回波損的比較,可看出故障線段的共同特點是衰減指標超標,其余2個指標回波損耗和串音都測試正常。通過室內檢修過程中的驗證試驗,成功找出了產生這類故障電纜的原因和解決方法,有效降低了428采集電纜的報廢率。
            Abstract:
            When seismic survey is conducted in saline alkali waters, some 428# link cables will be soaked in the salinealkaline water inevitably. Because of the strong erosion from the salinealkaline water, many 428# cables are found to have performance index error. Comparing with the good 428# cable in attenuation, crosstalk and return loss, the common feature of the faulty cables is excess in attenuation index, while the test results of crosstalk and return loss look good. The cause of this kind of faulty cable and repair method are successfully found out through the verification test in the indoor maintenance process, and the scrap rate of the 428# cables are reduced effectively.

            參考文獻/References:

            [1] 美國FLUKE公司. TX-LT用戶手冊[Z]. 2009
            [2] 何健. 數字通信電纜衰減特性分析[D]. 中國通信學會2013年光纜電纜學術年會,2013:1.
            [3] 史繼誠. 高分子材料的老化和防老化研究[D]. 大連交通大學環境科學與工程學院,2005:1-3.
            [4] 張紅. 高電壓技術[M]. 北京:中國電力出版社,2009:36.

            相似文獻/References:

            [1]朱立新.電動導入式打撈器的設計與應用[J].石油管材與儀器,2017,3(04):11.[doi:10.19459/j.cnki.61-1500/te.2017.04.003]
             ZHU Lixin.Design and Application of Electric Imported Type Fisher[J].Petroleum Tubular Goods & Instruments,2017,3(03):11.[doi:10.19459/j.cnki.61-1500/te.2017.04.003]

            備注/Memo

            備注/Memo:
            第一作者簡介:馮占江,男,1962年生,工程師, 現主要從事物探采集設備維修工作。E-mail:[email protected]
            更新日期/Last Update: 2018-06-25